Skip to content Skip to navigation menu
Looking for oligos? Visit our oligo and Stellaris dedicated platform at oligos.biosearchtech.com
 

You searched for "Cal Fluor"

Did you mean: cal flow?

How do I calibrate my instrument for the CAL Fluor® and Quasar® Dyes?

CAL Fluor® and Quasar® dye calibration standards are designed to improve the accuracy of signal detection in real-time thermal cyclers that require spectral calibration. They enable the instrument to store the fluorescence profile of each dye and control for channel cross-talk. Crosstalk is the bleed-through of fluorescent signal from a reporter into an adjacent filter or channel, an issue of particular concern in a multiplexed assay. Many qPCR machines are pre-calibrated for Cy™3 and Cy5 dyes. In those machines, no calibration is necessary to use our Quasar 570 (Cy3 alternative) and Quasar 670 (Cy5 alternative) dyes. To use our CAL Fluor dye labels, particularly in a multiplexing assay, certain real-time PCR instruments need to be calibrated to anticipate crosstalk. LGC Biosearch Technologies does not make available pure dyes. Instead, our calibration standards are formulated to better mimic a fluorescent probe under experimental conditions by covalently linking the dye to an oligo-thymidine (dT10).  A complete list of available Calibration and Reference Dyes is available through our website. Instructions to calibrate select qPCR machines are available in our Spectral Calibration Instructions.

Which dyes are compatible with my thermal cycler?

LGC Biosearch Technologies offers many common fluorophores including FAM, HEX and TAMRA dyes, as well as our own proprietary dyes. Our CAL Fluor® and Quasar® dye series span the spectrum with emission wavelengths ranging from yellow to far-red, and represent alternatives to dyes such as VIC®, Cy™3, Texas Red, LC Red® 640, Cy5, and Cy5.5. For your convenience we have compiled a Multiplexing Dye Recommendations Chart outlining optimal dye combinations in select qPCR machines, as well as a Fluorophore & BHQ® Dye Selection Chart listing reporter-quencher pairings. In addition, you may use our Spectral Overlay Tool to visualize the absorption and emission spectra of multiple dyes together.

Does LGC Biosearch Technologies make Safety Data Sheets (SDS) available?

Safety Data Sheets (SDS), formerly referred to as Material Safety Data Sheets (MSDS), are available for download under the Technical Specs or Related Info tabs found on most product webpages. If you are unable to access this document or need additional information, please contact our Technical Support team.

Can Amp-Seq technology be used in human clinical diagnostics?

AMPSEQ-001
Currently, we are unable to support human clinical diagnostic applications.

Why are genotype calls not achieved for specific targets?

AMPSEQ-001
Sometimes, despite a successful primer design for a target, genotyping calls are not achieved for a specific target. This can be caused by several issues including poor primer design and issues with the synthesis of the primers. In addition, if genomic reference data for both parental strains is not provided for target primer design, some primer pairs might not work for all F1 samples. Missing genotypes are generally attributed to low depth. Certain targets cannot be amplified because of sample quality issues or unknown parental bias in the genomes. Our standard design process addresses the parental bias by avoiding primers on known variability in the genome. Known variation information can be provided to us in the target flanking sequences through the Data Submission form.

Have you produced proteins at scale?

COMCEL-008

Our customers have reported growth of ClearColi strains in a 5 litre fermenter and shown optical density levels in excess of 150, and that some defoaming agents (particularly silicone-based defoamers) are beneficial while other defoaming agents such as polypropylene glycol may inhibit cell growth.

Does Amp-Seq One provide data analysis software to generate genotype calls? 

AMPSEQKIT1
Biosearch Technologies provides an analysis pipeline (the BiosearchCaller software), compatible with the Amp-Seq One technology, to produce genotypes from the sequencing data. The software can be accessed via a cloud system and our technical team will support the deployment and initial setup.

Why are genotype calls not achieved for specific targets?

AMPSEQKIT1

Sometimes, despite a successful primer design for a target, genotyping calls are not achieved for a specific target. This can be caused by several issues including poor primer design and issues with the synthesis of the primers. In addition, if genomic reference data for both parental strains is not provided for target primer design, some primer pairs might not work for all F1 samples.

Missing genotypes are generally attributed to low depth. Certain targets cannot be amplified because of sample quality issues or unknown parental bias in the genomes. Our standard design process addresses the parental bias by avoiding primers on known variability in the genome. Known variation information can be provided to us in the target flanking sequences through the Data Submission form.

Can I use other dyes besides the Green Fluorescent Dye available in the LavaLAMP™ DNA Component Kit with Dye?

Yes. Syto-13 (Molecular Probes) and EvaGreen (Biotium) have both been tested with the LavaLAMP DNA Master Mix and they perform well.

Are Endura High-Yield Electrocompetent Cells classified as genetically modified organisms (GMO)?

COMCEL-017
Depending on the definition of GMO, yes, they are GMO as they were constructed by methods outside of E. coli conjugations or viral transductions. However, they do not contain DNA from organisms other than E. coli.