Does LGC Biosearch Technologies make Safety Data Sheets (SDS) available?

Safety Data Sheets (SDS), formerly referred to as Material Safety Data Sheets (MSDS), are available for download under the Technical Specs or Related Info tabs found on most product webpages. If you are unable to access this document or need additional information, please contact our Technical Support team.

What reaction volumes can be used with RapiDxFire qPCR 5X Master Mix GF?

PCRAMP-012

RapiDxFire qPCR Master Mix has been validated for use in qPCR applications in 1.6 µL – 25 µL reaction volumes.

What is the minimal DNA concentration needed prior to starting the enzymatic fragmentation reaction?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

As stated above, you can use a minimum of 50 pg of DNA in your enzymatic fragmentation reaction. Since the maximal volume of input DNA is 12.3 µL for the End-repair/A-tailing Reaction, your digested DNA must be at a concentration >4.1 pg/µL.

Won’t the dyes in the primers affect my Illumina sequencing run and/or data quality?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

No. We’ve done extensive testing to demonstrate that the dyes do not affect the sequencing run/instruments or decrease the quality of the data generated. During the final library clean-up and size selection steps, the dyes are removed and therefore, do not make it on to the sequencer. To ensure compatibility in case of incomplete dye removal, we added the full concentration of dye found in the PCR amplification reactions to our final libraries and sequenced those samples on multiple instruments. Even with this artificially high concentration of dye in the denatured library (worst case scenario), we found no effect on the sequencing run/instrument performance or the yield and quality of the final data.

Is the NxSeq HT Dual Indexing Kit (Item. No. 15300-1) compatible with the NxSeq UltraLow DNA Library Prep Kit, 12 reactions (Item. No. 15012-2)?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

Yes. However if combining these two kits, you will be setting up fewer reactions, and you will need to add 2.5 µL aliquots of one 500 Series Primer and one 700 Series Primer to each library amplification reaction. Be extremely careful to avoid cross-contamination of the Indexed Primers when using only a portion of the supplied volume; open only one tube at a time, and ideally change gloves after closing one tube and before opening the next.

Are the NxSeq Single Indexing Kits (Item. No. 15100-1, 15200-1) compatible with the NxSeq UltraLow DNA Library Kit, 96 reactions (Item. No. 15096-2)?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

Yes. If you are doing lower multiplexing and only want/need single indexes, you can absolutely combine these kits. You will reduce the cost of your library prep by buying your library prep reagents in bulk.

What are the possible sources of duplicates in my sequencing data?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

Duplicate copies of sequences in your library can occur in several forms including: 1) biological duplicates; 2) PCR duplicates; 3) optical duplicates and 4) exclusion amplification (ExAmp) or proximity duplicates. Biological duplicates occur when you extract DNA from multiple cells/organisms and your DNA sample contains multiple genomes (copies). For example, a standard library made from 40 ng human genomic DNA can contain the equivalent of 5,714 genomes which translates into 5,714 potential exact copies of each ~300 bp insert whereas a 40 ng E. coli K12 library can contain over 7.8 M exact copies of each 300 bp insert. So as the size of the genome decreases, the number of potential biological duplicates increases with the same starting amount of DNA.

PCR duplicates are produced at each round of amplification; every amplification cycle produces another duplicate of each molecule. In an unbiased system (adaptor ligation/PCR) with 100% efficiency, PCR duplicates will not cause problems if you have adequate starting DNA that is not limiting for the capacity of the sequencer used. PCR duplication rates detected in the resulting output read files are also affected by the number of samples multiplexed per lane, the number of reads analysed per sample, and the capacity of the sequencer used. The figure below illustrates many of these effects. In this experiment, libraries were made from 50 pg, 500 pg or 75 ng of E. coli genomic DNA. The samples were pooled with other samples and run on a MiSeq with 2 x 150 bp chemistry. Different numbers of reads were sampled (indicated) from 100K up to 5.4M depending on the library, and the percent of CLC (software package) mapped duplicates was determined. As shown, even with 50 pg of input in this case, the maximal number of duplicates observed was 6%. Importantly and as expected, as the number of reads sampled decreased, the percentage of duplicates per library also decreased.

I’m seeing a lot of duplicates when I analyse my sequencing data generated on an Illumina sequencer with a patterned flow cell. Do you know the reason for these high duplication rates and is there a solution?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

The majority of these duplicates are likely proximity duplicates produced during ExAmp cluster formation on patterned flow cells. These duplicates occur independently of the library and their severity may vary from run to run. They can be removed bioinformatically using a program such as Clumpify (a part of the BBMap toolset available at https://sourceforge.net/projects/bbmap/), which can remove proximity and optical duplicates from a dataset, as well as perform quality trimming and adaptor filtering.

Are the Safety Data Sheets (SDS) available in other languages?

PCRAMP-105
Yes, please contact techsupport@LGCGroup.com

Are the Safety Data Sheets (SDS) available in other languages?

Yes, please contact techsupport@LGCGroup.com