What reaction volumes can be used with RapiDxFire qPCR 5X Master Mix GF?

PCRAMP-012

RapiDxFire qPCR Master Mix has been validated for use in qPCR applications in 1.6 µL – 25 µL reaction volumes.

Does LGC Biosearch Technologies make Safety Data Sheets (SDS) available?

Safety Data Sheets (SDS), formerly referred to as Material Safety Data Sheets (MSDS), are available for download under the Technical Specs or Related Info tabs found on most product webpages. If you are unable to access this document or need additional information, please contact our Technical Support team.

Do you have data indicating concordance of Amp-Seq One with other technologies? 

AMPSEQKIT1

LGC has a large number of internal datasets demonstrating concordance of Amp-Seq One results with Amp-Seq, which in turn has been tested for concordance with alternative technologies including Flex-Seq. We tested a panel of diverse samples with Flex-Seq and Amp-Seq with a concordance of 98.82%. Concordance between Amp-Seq and Amp-Seq One is 98.19%. If you would like more information, please contact techsupport@lgcgroup.com

Does Amp-Seq One provide data analysis software to generate genotype calls? 

AMPSEQKIT1
Biosearch Technologies provides an analysis pipeline (the BiosearchCaller software), compatible with the Amp-Seq One technology, to produce genotypes from the sequencing data. The software can be accessed via a cloud system and our technical team will support the deployment and initial setup.

Are the Safety Data Sheets (SDS) available in other languages?

PCRAMP-105
Yes, please contact techsupport@LGCGroup.com

What are the possible sources of duplicates in my sequencing data?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

Duplicate copies of sequences in your library can occur in several forms including: 1) biological duplicates; 2) PCR duplicates; 3) optical duplicates and 4) exclusion amplification (ExAmp) or proximity duplicates. Biological duplicates occur when you extract DNA from multiple cells/organisms and your DNA sample contains multiple genomes (copies). For example, a standard library made from 40 ng human genomic DNA can contain the equivalent of 5,714 genomes which translates into 5,714 potential exact copies of each ~300 bp insert whereas a 40 ng E. coli K12 library can contain over 7.8 M exact copies of each 300 bp insert. So as the size of the genome decreases, the number of potential biological duplicates increases with the same starting amount of DNA.

PCR duplicates are produced at each round of amplification; every amplification cycle produces another duplicate of each molecule. In an unbiased system (adaptor ligation/PCR) with 100% efficiency, PCR duplicates will not cause problems if you have adequate starting DNA that is not limiting for the capacity of the sequencer used. PCR duplication rates detected in the resulting output read files are also affected by the number of samples multiplexed per lane, the number of reads analysed per sample, and the capacity of the sequencer used. The figure below illustrates many of these effects. In this experiment, libraries were made from 50 pg, 500 pg or 75 ng of E. coli genomic DNA. The samples were pooled with other samples and run on a MiSeq with 2 x 150 bp chemistry. Different numbers of reads were sampled (indicated) from 100K up to 5.4M depending on the library, and the percent of CLC (software package) mapped duplicates was determined. As shown, even with 50 pg of input in this case, the maximal number of duplicates observed was 6%. Importantly and as expected, as the number of reads sampled decreased, the percentage of duplicates per library also decreased.

I’m seeing a lot of duplicates when I analyse my sequencing data generated on an Illumina sequencer with a patterned flow cell. Do you know the reason for these high duplication rates and is there a solution?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

The majority of these duplicates are likely proximity duplicates produced during ExAmp cluster formation on patterned flow cells. These duplicates occur independently of the library and their severity may vary from run to run. They can be removed bioinformatically using a program such as Clumpify (a part of the BBMap toolset available at https://sourceforge.net/projects/bbmap/), which can remove proximity and optical duplicates from a dataset, as well as perform quality trimming and adaptor filtering.

Can Endura High-Yield Electrocompetent Cells be grown in minimal media?

COMCEL-017
Yes, however, in addition to the induction solution Endura High-Yield Electrocompetent Cells require supplementation with 1 mM proline/leucine and 1 g/ml thiamine and will have lower plasmid yields than identical cells grown in rich media.

What is the difference between RapiDxFire™ qPCR 5X Master Mix GF and BHQ™ Probe Master Mix?

PCRAMP-012

RapiDxFire qPCR 5X Master Mix GF is a 5X qPCR master mix produced and purified in a quality standard ISO 13485-certified manufacturing facility, allowing for its use in molecular diagnostic and clinical applications.

BHQ Probe Master Mix is a 2X PCR master mix, which has been validated for both endpoint genotyping and qPCR applications. It has been designed specifically to be inhibitor-tolerant, especially when working with crude-extracted agrigenomic samples (e.g. leaves, seeds).