What is the minimal DNA concentration needed prior to starting the enzymatic fragmentation reaction?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

As stated above, you can use a minimum of 50 pg of DNA in your enzymatic fragmentation reaction. Since the maximal volume of input DNA is 12.3 µL for the End-repair/A-tailing Reaction, your digested DNA must be at a concentration >4.1 pg/µL.

Won’t the dyes in the primers affect my Illumina sequencing run and/or data quality?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

No. We’ve done extensive testing to demonstrate that the dyes do not affect the sequencing run/instruments or decrease the quality of the data generated. During the final library clean-up and size selection steps, the dyes are removed and therefore, do not make it on to the sequencer. To ensure compatibility in case of incomplete dye removal, we added the full concentration of dye found in the PCR amplification reactions to our final libraries and sequenced those samples on multiple instruments. Even with this artificially high concentration of dye in the denatured library (worst case scenario), we found no effect on the sequencing run/instrument performance or the yield and quality of the final data.

Can RapiDxFire qPCR 5X Master Mix GF be used in multiplex reactions?

PCRAMP-012

Yes, RapiDxFire qPCR 5X Master Mix GF has been optimised for use in multiplex qPCR applications and customers can chose from a wide range of fluorophores from Biosearch Technologies, depending on their qPCR instrument.

When performing multiplexing reactions, we recommend optimising each assay as a singleplex reaction, before combining a multiplex, to evaluate the optimal parameters of each assay (e.g. annealing temperature, cycling conditions etc.)

Does the RapiDxFire qPCR 5X Master Mix GF contain a passive reference dye?

PCRAMP-012

No, the RapiDxFire qPCR 5X Master Mix GF does not contain a passive reference dye. However, customers can supplement their reaction mix with a passive reference dye of their choice.

Are there any limitations on the types of fluorescent reporter molecules I can use with RapiDxFire qPCR 5X Master Mix GF?

PCRAMP-012

All fluorescent dyes listed on our Fluorophore and BHQ Selection Chart are available for use with RapiDxFire qPCR 5X Master Mix GF, in which the corresponding BHQ dye has been identified.

Can RapiDxFire qPCR 5X Master Mix GF be used for both endpoint genotyping and qPCR applications?

PCRAMP-012

RapiDxFire qPCR 5X Master Mix GF has been validated to be highly sensitive in qPCR applications, for use in the clinical and molecular-diagnostic market. Its use for end-point genotyping has not been validated, however it may be used as such with the understanding that any data generated or inference of clinical results is subject to your own validation and quality control criteria thresholds.

What are the optimum thermal cycling conditions when working with RapiDxFire qPCR 5X Master Mix GF?

PCRAMP-012

The thermal cycling conditions will depend various factors. For example, the annealing temperature will depend on the sequence of the target-specific primers and probes used in the reaction, and the number of cycles will be dependent on the efficiency of the PCR reaction. Please refer to the RapiDxFire qPCR 5X Master Mix GF user guide for further information on recommended protocols and adhering to the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) Guidelines.

Can Endura High-Yield Electrocompetent Cells be grown in minimal media?

COMCEL-017
Yes, however, in addition to the induction solution Endura High-Yield Electrocompetent Cells require supplementation with 1 mM proline/leucine and 1 g/ml thiamine and will have lower plasmid yields than identical cells grown in rich media.

Does LGC Biosearch Technologies make Safety Data Sheets (SDS) available?

Safety Data Sheets (SDS), formerly referred to as Material Safety Data Sheets (MSDS), are available for download under the Technical Specs or Related Info tabs found on most product webpages. If you are unable to access this document or need additional information, please contact our Technical Support team.