Skip to content Skip to navigation menu
Looking for oligos? Visit our oligo and Stellaris dedicated platform at oligos.biosearchtech.com
 

You searched for "wa 012 2010 510 kontraktor pemborong interior rural minimal sederhana ukuran 800x600 data ponjong gunungkidul"

Does LGC Biosearch Technologies make Safety Data Sheets (SDS) available?

Safety Data Sheets (SDS), formerly referred to as Material Safety Data Sheets (MSDS), are available for download under the Technical Specs or Related Info tabs found on most product webpages. If you are unable to access this document or need additional information, please contact our Technical Support team.

What is the minimal DNA concentration needed prior to starting the enzymatic fragmentation reaction?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

As stated above, you can use a minimum of 50 pg of DNA in your enzymatic fragmentation reaction. Since the maximal volume of input DNA is 12.3 µL for the End-repair/A-tailing Reaction, your digested DNA must be at a concentration >4.1 pg/µL.

Won’t the dyes in the primers affect my Illumina sequencing run and/or data quality?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

No. We’ve done extensive testing to demonstrate that the dyes do not affect the sequencing run/instruments or decrease the quality of the data generated. During the final library clean-up and size selection steps, the dyes are removed and therefore, do not make it on to the sequencer. To ensure compatibility in case of incomplete dye removal, we added the full concentration of dye found in the PCR amplification reactions to our final libraries and sequenced those samples on multiple instruments. Even with this artificially high concentration of dye in the denatured library (worst case scenario), we found no effect on the sequencing run/instrument performance or the yield and quality of the final data.

I’m seeing a lot of duplicates when I analyse my sequencing data generated on an Illumina sequencer with a patterned flow cell. Do you know the reason for these high duplication rates and is there a solution?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

The majority of these duplicates are likely proximity duplicates produced during ExAmp cluster formation on patterned flow cells. These duplicates occur independently of the library and their severity may vary from run to run. They can be removed bioinformatically using a program such as Clumpify (a part of the BBMap toolset available at https://sourceforge.net/projects/bbmap/), which can remove proximity and optical duplicates from a dataset, as well as perform quality trimming and adaptor filtering.

Do you have data indicating concordance of Amp-Seq with other technologies?

AMPSEQ-001

Biosearch Technologies have internal data demonstrating concordance of Amp-Seq results with alternative technologies including Flex-Seq. We tested a panel of diverse samples with Flex-Seq and Amp-Seq with a concordance of 98.82%. If you would like more information about this, please contact techsupport@lgcgroup.com.

Does Amp-Seq provide data analysis software to generate genotype calls?

AMPSEQ-001
Biosearch Technologies provides an analysis pipeline (the BiosearchCaller software), compatible with the Amp-Seq technology, to produce genotypes from the sequencing data. The software can be accessed via a cloud system and our technical team will support the deployment and initial setup.

Are the Safety Data Sheets (SDS) available in other languages?

PCRAMP-105
Yes, please contact techsupport@LGCGroup.com

Are the Safety Data Sheets (SDS) available in other languages?

Yes, please contact techsupport@LGCGroup.com

Are the Safety Data Sheets (SDS) available in other languages?

PCRAMP-104
Yes, please contact techsupport@LGCGroup.com

What reaction volumes can be used with RapiDxFire qPCR 5X Master Mix GF?

PCRAMP-012

RapiDxFire qPCR Master Mix has been validated for use in qPCR applications in 1.6 µL – 25 µL reaction volumes.