Can Amp-Seq technology be used in human clinical diagnostics?

AMPSEQ-001
Currently, we are unable to support human clinical diagnostic applications.

Do you have any recommendations for purifying DNA from difficult biological samples such as plant leaves and seeds before shearing?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

No. We do not have any specific recommendations for DNA purification. However, the purified DNA should be high quality with A260/280 ratios above 1.8. The DNA should also be free of detectable RNA contamination. Prior to shearing/fragmentation, the purified DNA samples can be analysed on 0.7% agarose gel to check for sample degradation and RNA contamination.

Should I use electrocompetent or chemically competent cells to make my library?

We recommend using electrocompetent cells for library generation, because the transformation efficiency for electrocompetent cells is higher. Higher transformation efficiency preserves library diversity.

Which instruments can be used to monitor the real-time fluorescent assays?

See the User Manual for a list of instruments that have been tested at Biosearch Technologies. Basically, any instrument capable of maintaining stable reaction temperatures and detecting fluorescence in the FAM (fluorescein) channel will work.

How do you determine the brightness of a dye?

The absolute intensity of a dye is a product of the extinction coefficient and the quantum yield. We have not measured the quantum yield for our dyes as this value is highly dependent upon the local environment, including the buffer system used for the measurement. However, we do provide the extinction coefficients for dye modifications at their lambda max wavelength, and these values are available under the Technical Specs tabs of our Oligo Modifications webpages. While quantum yield and extinction coefficients both contribute to dye detectability, the principal determinant for Stellaris® RNA FISH assays is actually the instrument optics, including the excitation source, available filters, and quantum efficiency of the camera.

Are there specific recommendations for performing 1-step RT-qPCR on RNA isolated from clinical samples?

PCRAMP-021

The nucleic acid (either DNA or RNA) will most likely need to be purified from clinical samples due to sample/transport media specific inhibitors and RNAses. For example, for RNA purification, we recommend our sbeadex‚Ñ¢ Pathogen Nucleic Acid Purification Kit for optimal purification.

Does Amp-Seq One provide data analysis software to generate genotype calls? 

AMPSEQKIT1
Biosearch Technologies provides an analysis pipeline (the BiosearchCaller software), compatible with the Amp-Seq One technology, to produce genotypes from the sequencing data. The software can be accessed via a cloud system and our technical team will support the deployment and initial setup.

There are transformation protocols for chemically competent cells that do not include a heat shock. Do I need to heat shock my competent cells?

We have not tested alternative transformation protocols extensively. You can avoid the heat shock step, but it is highly likely that your transformation efficiencies will decrease.

What purification scale is sbeadex Lightning suitable for?

SBXLCK, SBXLCKSTART

The standard protocol assumes a 200 µL volume of lysate for each purification. The purification protocol can be upscaled or downscaled depending on laboratory requirements. We do not provide different scales of kits (e.g. mini, maxi); instead core kit reagents and additional reagents can be adjusted to suit your specific laboratory process.