Skip to content Skip to navigation menu
Looking for oligos? Visit our oligo and Stellaris dedicated platform at oligos.biosearchtech.com
 

You searched for "Cal Fluor"

Did you mean: cal flow?

  • 1
  • 2(current)
  • 3

Do you have any recommendations for purifying DNA from difficult biological samples such as plant leaves and seeds before shearing?

NXGSEQ-003, NXGSEQ-004, 15300-1, NXGSEQ-001, NXGSEQ-002

No. We do not have any specific recommendations for DNA purification. However, the purified DNA should be high quality with A260/280 ratios above 1.8. The DNA should also be free of detectable RNA contamination. Prior to shearing/fragmentation, the purified DNA samples can be analysed on 0.7% agarose gel to check for sample degradation and RNA contamination.

Why are genotype calls not achieved for specific targets?

AMPSEQ-001
Sometimes, despite a successful primer design for a target, genotyping calls are not achieved for a specific target. This can be caused by several issues including poor primer design and issues with the synthesis of the primers. In addition, if genomic reference data for both parental strains is not provided for target primer design, some primer pairs might not work for all F1 samples. Missing genotypes are generally attributed to low depth. Certain targets cannot be amplified because of sample quality issues or unknown parental bias in the genomes. Our standard design process addresses the parental bias by avoiding primers on known variability in the genome. Known variation information can be provided to us in the target flanking sequences through the Data Submission form.

Are there any limitations on the types of fluorescent reporter molecules I can use with BHQ Probe Master Mix?

BHQ-001

All fluorescent dyes listed on our Fluorophore and BHQ Selection Chart are available for use with BHQ Probe Master Mix, in which the corresponding BHQ dye has been identified.

Why are genotype calls not achieved for specific targets?

AMPSEQKIT1

Sometimes, despite a successful primer design for a target, genotyping calls are not achieved for a specific target. This can be caused by several issues including poor primer design and issues with the synthesis of the primers. In addition, if genomic reference data for both parental strains is not provided for target primer design, some primer pairs might not work for all F1 samples.

Missing genotypes are generally attributed to low depth. Certain targets cannot be amplified because of sample quality issues or unknown parental bias in the genomes. Our standard design process addresses the parental bias by avoiding primers on known variability in the genome. Known variation information can be provided to us in the target flanking sequences through the Data Submission form.

Are Endura High-Yield Electrocompetent Cells classified as genetically modified organisms (GMO)?

COMCEL-017
Depending on the definition of GMO, yes, they are GMO as they were constructed by methods outside of E. coli conjugations or viral transductions. However, they do not contain DNA from organisms other than E. coli.

How do I calculate transformation efficiency (TE)?

TE = (# colonies) / (µg DNA transformed) * (final transformation volume) / (volume plated) * dilution factor = cfu / µg

For example, if you transformed 1 ng of plasmid DNA into cells, diluted the transformation to a final volume of 1000 µL with Recovery Medium, then plated 25 µL of a 1:100 dilution of that transformation, and the next day you counted 150 colonies on your plate, your calculation would look like this:

# of colonies: 150
µg DNA transformed: 0.001
Final tansformation volume = 1000 µL
Volume plated = 25 µL
Dilution factor = 1 µL into 100 µL, 100-fold (factor of 100)

TE = (150 / 0.001) * (1000 / 25) * 100 = 6 x 108 cfu / µg

Can I use other dyes besides the Green Fluorescent Dye available in the LavaLAMP™ DNA Component Kit with Dye?

Yes. Syto-13 (Molecular Probes) and EvaGreen (Biotium) have both been tested with the LavaLAMP DNA Master Mix and they perform well.

What purification scale is sbeadex Lightning suitable for?

SBXLCK, SBXLCKSTART

The standard protocol assumes a 200 µL volume of lysate for each purification. The purification protocol can be upscaled or downscaled depending on laboratory requirements. We do not provide different scales of kits (e.g. mini, maxi); instead core kit reagents and additional reagents can be adjusted to suit your specific laboratory process.

Which instruments can be used to monitor the real-time fluorescent assays?

See the User Manual for a list of instruments that have been tested at Biosearch Technologies. Basically, any instrument capable of maintaining stable reaction temperatures and detecting fluorescence in the FAM (fluorescein) channel will work.

Can I use other dyes besides the Green Fluorescent Dye available in the LavaLAMP™ DNA Master Mix with Dye?

Yes. Syto-13 (Molecular Probes) and EvaGreen (Biotium) have both been tested with the LavaLAMP DNA Master Mix and they perform well.