MicroPure II Column
BTI's MicroPure II columns (MP-1602) are intended for Reversed-phase purification of 5'-dimethoxytrityl protected oligonucleotides followed by on-column detritylation. The cartridge consists of a 5 mL syringe barrel packed with 200 mg of high performance hydrophobic polymeric resin. The method relies on strong binding between the 5'-DMT protected product and the resin, thus allowing separation from the most common impurities, truncated sequences, which do not bind. Treatment with acid removes the DMT group from the product, the desired product (free from organic residues) is eluted with 20% acetonitrile. The method is rapid, efficient and many samples can be purified simultaneously. At least 1 µmol or 50 O.D's of crude DNA can be applied to the column. The purified yield will depend, in each case, on sequence length and the quality of the crude sample.
Properties:
- Chemical Name:
- MicroPure II Column
Product usage:
- Additional information:
- 1. Program DNA synthesizer to leave terminal 5'-DMT group attached;
2. Cleave and deprotect product with conc. aqueous ammonia;
3. Evaporate cleavage solution to dryness;
4. Re-suspend in 1ml 0.1N TEAA or H2O;
5. Pre-equilibrate the column by passing 4mL of acetonitrile through the column;
6. Repeat with 6mL of 1N TEAA (triethylamine acetate);
7. Take the oligo solution of step 4 and apply slowly to the column while collecting effluent in a separate micro-centrifuge tube. Reload effluent and pass once more through column (optional);
8. To elute failures pass 20 mL (2mL at a time) of 12% MeCN/ 0.1N TEAA through the column;
9. Rinse the column with 6mL of water;
10. Pass 4mL (2 at a time) of 2.5% TFA through the column, wait 5 minutes;
11. Pass 6mL or more of water through column. Check to see pH is neutral.
12. Slowly pass 10mL of 20% acetonitrile/water through the column, collecting effluent containing the desired purified product in a labeled microcentrifuge tube;
13. Speedvac ™ the solution to dryness, analyze and use as desired.
Storage and handling:
- Storage and handling:
- Ambient
- Storage conditions:
- Room Temperature
Related info
Trademarks
Biosearch, the Biosearch Technologies logo, Black Hole Quencher, BHQ, BHQplus, CAL Fluor, Quasar, Pulsar, Stellaris and SuperROX are registered trademarks of Biosearch Technologies, Inc.
Permitted Product Usage
All products offered for sale by Biosearch Technologies, Inc. (BTI) are sold under the condition that they be used for research purposes only and are prohibited from use in diagnostic or other commercial applications unless explicitly authorized by separate written agreement with BTI.
Black Hole Quencher® (BHQ), CAL Fluor®, Quasar® and Pulsar® dyes (referred to collectively as “BTI Dyes”) are sold to the purchaser only for internal R&D use, and are not to be used for clinical or diagnostic purposes. Neither the BTI Dyes nor the compounds synthesized with them are to be re-packaged or re-sold. Separate licenses to the BTI Dyes may be available for applications other than the aforementioned internal R&D. Please inquire via info@biosearchtech.com.
Patents
The Black Hole Quencher dye technology is protected in the United States and other countries by U.S. patents and continuations numbered 7,019,129, 7,019,129B1, 7,109,312B2, 7,582,432, 8,410,255B2 and 8,440,399B2 issued to Biosearch Technologies, Inc. The CAL Fluor technology is covered by U.S. patent number 7,344,701B2. The Quasar technology is covered by U.S. Patent numbers 7,705,150B2, 7,868, 157B2 and 8,436,153B2. The Pulsar technology is covered by U.S. Patent numbers 7,635,762B2 and 8,119,781B2.
Supercolumns are protected by U.S. Patent 6,761,855 B1, "Column for solid phase processing" issued to Biosearch Technologies, Inc. Contact licensing@biosearchtech.com for more information. Supercolumns for use on ABI 3900 or equivalent rotary cartridge style shoulder mount design are also manufactured under license from McLuen Design, U.S. Patents 8,158,085 and 8,404,196.
Stellaris products are sold under license from Rutgers University and may be used under its patent rights for Research Use Only.
Licensing
Information on licensing programs for the commercial and/or diagnostic use of these products is available by contacting licensing@biosearchtech.com.
Please visit our legal webpage on www.biosearchtech.com for full legal disclosure.