Biosearch Technologies is part of LGC Diagnostics & Genomics – Learn More
CPG column for incorporation of a 2'-fluoro modified ribo-G nucleobase at the 3' end of an oligonucleotide.
Usually shipped in 5-10 Days, Made To Order
2'-F-RNA oligonucleotides adopt an A-form helix on hybridisation to a target. Whereas a hydroxyl group of RNA is a hydrogen bond donor, fluorine appears to be a weak acceptor. These features of 2'-F-RNA oligonucleotides lead to certain interesting properties. For example, it was demonstrated that oligonucleotides hybridise to a RNA oligonucleotide in the following order of increasing stability: DNA < RNA < 2'-OMe-RNA < 2'-F-RNA. (1) Aptamers composed of 2'-F–RNA bind targets with higher affinities and are more resistant to nucleases, compared to RNA aptamers. (2) In addition, 2'-F-RNA can be effectively used in siRNA applications. It has been shown that siRNA synthesised with 2'-F pyrimidine nucleosides are more inhibitory, and show considerably increased stability in human plasma, compared to siRNA. (3) 2'-F-RNA is now finding a number of applications, especially in RNA interference for the specific silencing of genes in cells and in vivo. (4) We provide a range of 2'-F phosphoramidites and CPGs, with a variety of pore sizes and linkers consistent with our unmodified DNA and RNA CPG products. The protecting group strategies are compatible with the usual DNA and RNA chemistries.
Ref:
|
Synthesizer
|
Column
|
Type/Description
|
Notes
|
|---|---|---|---|
|
MerMade 6,12
|
MerMade, syringe (all scales)
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
|
MerMade 4, 48X, 96E, 192E, 192X
|
MerMade, Syringe (up to 1.3 mL)
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
|
ABI 384 / 394
|
Luer
|
Barrel column with luer fitting at either end
|
Also known as ALL-FIT or Standard
|
|
Expedite 8909
|
Luer
|
Barrel column with luer fitting at either end
|
Also known as ALL-FIT or Standard
|
|
ABI3900
|
MerMade
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
|
K&A H4, H8, H8SE, H2, H32, H64
|
Luer
|
Barrel column with luer fitting at either end
|
Also known as ALL-FIT or Standard
|
|
K&A S4CL/S8CL
|
Luer
|
Barrel column with luer fitting at either end
|
Also known as Standard. For this instrument, we recommend the Luer (Standard) column as the ALL-FIT columns have a wider barrel.
|
|
Dr Oligo 48
|
MerMade
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
|
Dr Oligo 192XLc, 768XLc just plates
|
MerMade, Syringe (up to 1.3 mL)
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
|
OligoMaker X12, 48, 192, X192, X96
|
MerMade, Syringe (up to 1.3 mL)
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
Need some support with placing an order, setting up an account, or finding the right protocol?
Contact us| Europe, Middle East, and Africa | |
|---|---|
| UK | +44 1992 470 757 |
| Germany | +49 30 1663 54600 |
| North America, Latin America | |
| Wisconsin, USA | +1 888 575 9695 |
| Asia Pacific | |
| China | +8621-22509000 |
| Singapore | +65 6734 4800 |